Up & Accent Lights
Installation Detail 2217
|
The image below requires the Whip! driver from Autodesk to be installed. Click to install the driver now.
Once installed, you may zoom, pan, plot or save this detail by clicking on the right mouse button to active the menu.
You may also drag and drop it into an AutoCAD drawing. To do this, hold down the CONTROL key while dragging and drop it into AutoCAD R14 via the INSERT command, or hold down both the SHIFT and CONTROL keys to perform an OPEN command.
INSTALLATION INSTRUCTIONS
FOR LOW VOLTAGE UP AND ACCENT LIGHTS
| FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAX.
WARNING: Fixture must be installed in accordance with local codes of the National Electrical Code (NEC). Failure to do so may result in serious injury and/or damage to the fixture.
SAFETY WARNING: Fixture can become very hot depending upon the lamp wattage used. Lens and metal around the lamp can become hot enough to blister hands. Particular care should be take no to locate fixtures where small children can reach them if high wattage lamps are used.
LUMINARIES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05 M) OF A POOL OR SPA. |
| TOOLS REQUIRED FOR INSTALLATION: |
|
|
- To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
- Dig hole to appropriate depth allowing the top two (2) inches of the fixture to remain above ground (see figure).
NOTE: Fixture is not submersible and shrud portion of fixture must be installed above ground to prevent rain and irrigation water from entering the fixture.
- Place fixture in the hole at the desired angle (see figure).
NOTE: Avoid aiming fixture directly upward. Whenever possible, set at angle to prevent rain or irrigation water water from settling on the lens.
- Strip the two (2) leads from the fixture wire. Using the two (2) silicone filled safety connectors (supplied). connect the leads from the fixture to the main supply cable leads (see fixgure).
NOTE: Fixtures are supplied with 36" of 18-2 pigtail for secure connection to the main supply cable. always coil extra cable not used below fixture for future relocation if desired.
IMPORTANT SAFETY INSTRUCTIONS:
LIGHTED LAMP IS HOT!!
WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
- Turn off / unplug and allow to cool before replacing lamp.
- Lamps get HOT quickly! Contact only switch/plug when turning on.
- Do not touch hot lens, guard or enclosures.
- Keep lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
- Do not operate luminare fitting with a missing or damaged shield (cover).
SAVE THESE INSTRUCTIONS
|
LAMP INSTALLATION / REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on fixture label.
- To prevent electrical shock, disconnect transformer from electrical supply before service.
- Loosen screw from shroud.
- Remove shroud to expose lamp.
- Replace lamp with correct wattage and type of lamp marked on fixture label.
NOTE: DO NOT touch Halogen lamp with bare hands. Always use the plastic bag (if available) to handle the lamp.
- Re-install shroud and tighten screw.
|