Well Lights
Installation Detail 5260
|
The image below requires the Whip! driver from Autodesk to be installed. Click to install the driver now.
Once installed, you may zoom, pan, plot or save this detail by clicking on the right mouse button to active the menu.
You may also drag and drop it into an AutoCAD drawing. To do this, hold down the CONTROL key while dragging and drop it into AutoCAD R14 via the INSERT command, or hold down both the SHIFT and CONTROL keys to perform an OPEN command.
INSTALLATION INSTRUCTIONS FOR LOW VOLTAGE WELL LIGHTS
| FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAX.
WARNING: Fixture must be installed in accordance with local codes of the National Electrical Code (NEC). Failure to do so may result in serious injury and/or damage to the fixture.
SAFETY WARNING: Fixture can become very hot depending upon the lamp wattage used. Lens and metal around the lamp can become hot enough to blister hands. Particular care should be take no to locate fixtures where small children can reach them if high wattage lamps are used.
LUMINARIES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05 M) OF A POOL OR SPA. |
| TOOLS REQUIRED FOR INSTALLATION: |
|
|
|
- To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
- Dig hole to appropriate depth allowing for 3" to 4" of pea gravel to surround the fixture (see figure).
- Strip the two (2) leads from the fixture wire. Using the two (2) silicone filled safety connectors (supplied) connect the leads from the fixture to the main supply cable leads (see figure).
Note: Fixtures are supplied with 36" of 18-2 cable pigtail for secure connection to the main supply cable.
Always coil extra cable not used below fixture for future relocation if desired.
PRECAUTION: Fixture is not submersible and adequate drainage must be provided during installation. It is recommended that the fixture be surrounded by 3" to 4" of pea gravel to assure proper drainage. Top of fixture must be above grade so rain and irrigation water can not accumulate for long periods of time (see figure).
IMPORTANT SAFETY INSTRUCTIONS:
LIGHTED LAMP IS HOT!!
WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
- Turn off / unplug and allow to cool before replacing lamp.
- Lamps get HOT quickly! Contact only switch/plug when turning on.
- Do not touch hot lens, guard or enclosures.
- Keep lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
- Do not operate luminare fitting with a missing or damaged shield (cover).
SAVE THESE INSTRUCTIONS
|
LAMP INSTALLATION / REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on fixture label.
- To prevent electrical shock, disconnect transformer from electrical supply before service.
- Loosen the four (4) cover screws and remove cover.
- Remove O-Ring.
- Replace lamp with correct wattage and type of lamp marked on fixture label.
Note: DO NOT touch Halogen lamp with bare hands. Always use a soft cloth or the plastic wrapping (if available) from the lamp to handle the lamp.
- Clean O-Ring and channel and re-install O-Ring.
Note: O-Ring channel must be cleaned and free of debris before replacing cover.
- Re-install cover and tighten the four (4) screws evenly.