Hydro-Flow Flowmeters
Hydroflow
Model 1200 Specifications
|
Mechanical
Specifications
|
|
Type
|
Full Bore, Inline
|
|
Measurable Fluids
|
Water; Water-based Mixtures;
Condensate
|
|
Pipe Sizes
|
1, 1.5, 2, 2.5, 3 in. (25 -
80mm)
|
|
Fluid Temperature
|
32 to 212 °F (0 to 100 °C)
|
|
Fluid Pressure
|
150 psi maximum
|
|
Ambient Temperature
|
– 20 to 140 °F (– 29 to 60
°C)
|
|
Flow Range
|
0.5 feet, or 0.15 meters, per
second minimum 15 feet, or 4.5 meters, per second
maximum
|
|
Measuring Units
|
English
|
Gallons
|
|
Metric
|
Cubic Meters
|
|
Other
|
Other measuring units available
upon request or measuring units can be reconfigured
using Hydro-Flow's Field-Pro, PC compatible
configuration software.
|
|
Accuracy
(Combined
Linearity & Repeatability)
|
± 0.5% of full scale
|
|
Wetted Parts
|
Vortex Sensor
|
Ultem (Plastic)
|
|
Shedder Bar
|
316 Stainless Steel
|
|
Flowmeter Body
|
Brass
|
|
Stem
|
Brass
|
|
O-rings
|
EPDM
|
|
Pipe Connection
|
NPT female
|
|
Straight Run Piping
|
Typical 10 diameters upstream,
5 diameters downstream
|
|
Electrical
Specifications
|
|
Enclosure
|
Reinforced Polycarbonate, NEMA
6
|
|
European CE Mark
|
Approved
|
|
Output Signal Options
|
Pulse Output
|
Frequency proportional to flow
rate or pulse proportional . Maximum pulse width is 5
ms; For other pulse widths, use the Fludiyne’s Relay
Output Module. See Measurable Flow Rates for standard
output scaling.
|
|
Analog Output
|
4-20 mA analog current loop,
current proportional to flow rate. 4 mA = zero flow; 20
mA = maximum flow listed in Measurable Flow Rates.
|
|
No Output
|
Display only. Power Supply:
|
|
Power Supply
|
Pulse Output
|
10-32 VDC power supply with
current limited by series resistance to between 5 and 20
mA.
|
|
Analog Output
|
10-32 VDC compliance.
|
|
No Output
|
8-32 VDC, 4 mA maximum.
|
|
Display Option
|
LCD display alternately shows
4-digit rate and 8-digit total flow.
|
|