A Valve for Those With a Different Slant on Installations
If your system’s main line is deeper than its lateral
line, Hunter has a valve created exclusively for your needs.
The angle version of the PGV offers all the great features
that you’ve come to expect in a Hunter valve, plus a design
equipped to handle the special configurations of your
installations. While many would consider the use of such a
product to be somewhat non-traditional, the PGV angle actually
boasts a flow characteristic that provides less friction loss
than you’ll find in a globe version valve in a more
“traditional” system layout. Thus, the PGV angle can be an
ideal choice for irrigation systems that have to operate off
of low water pressure.
|
|
Models
PGV-100G - 1" plastic globe valve
PGV-101G - 1" plastic globe valve with flow
control
PGV-100A - 1" plastic angle valve
PGV-101A - 1" plastic angle valve with flow
control
PGV-100MM - 1" plastic globe valve, male x male
threads
PGV-101MM - 1" plastic globe valve , with flow
control, male x male threads
PGV-100MB - 1" plastic globe valve, male thread
x barb
PGV-101MB - 1" plastic globe valve , with flow
control, male thread x barb
PGV-151 - 1 1/2" plastic globe/angle valve with
flow control
PGV-201 - 2" plastic globe/angle valve with flow
control
Dimensions
- 1" Globe - 5" H (13 cm) x 4 1/2" L
(11 cm) x 2 1/2" W (6 cm)
- 1" Angle - 5 1/2" H (14 cm) x 3 1/2"
L (9 cm) x 2 3/4" W (7 cm)
- 1 1/2" Globe/Angle - 7 1/2" H (19.1 cm) x
5 3/4" L (14.6 cm) x 4 1/2" W (10.8 cm)
- 2" Globe/Angle - 8" H (20.3 cm) x 6
3/4" L (17.1 cm) x 5 1/4" W (13.3 cm)
- Female Inlet/Outlet - 1", 1 1/2", 2" NPT, BSP
or Slip
Operating Specifications
- Flow: 1 to 120 gpm (0.23 to 27.2 m3/hr; 3.8 to 454.2 l/min)
- Pressure: 20 to 150 psi (1.4 to 10.3 bars; 138 to 1034 kPa)
- Heavy-duty solenoid: 24VAC, 370mA inrush current, 190mA holding
current, 60 cycles!
- 475mA inrush current, 230mA holding current, 50 cycles
Options Available
- Accu-Set™ pressure regulator
- Reclaimed water identification handle
- DC latching solenoid for use with battery-operated systems
PRODUCT
EXPLANATION
|
| EXAMPLE:
PGV
- 100G - S - AS |
PGV-100G
= 1", Globe Valve, no flow control
PGV-101G = 1", Globe Valve, with flow control
PGV-100A = 1", Angle Valve, no flow control
PGV-101A = 1", Angle Valve, with flow control
PGV-100MB = 1", Globe Valve, no flow control, male
thread x barb
PGV-101MB = 1", Globe Valve, with flow control,
male thread x barb
PGV-100MM = 1", Globe Valve, no flow control, male
x male
PGV-101MM = 1", Globe Valve, with flow control,
male x male
PGV-151 = 1 1/2", Globe/Angle, with flow control
PGV-201 = 2", Globe/Angle, with flow control |
OPTIONS
S = Slip x Slip (1" models only)
B = BSP Threads |
OPTIONS
USER INSTALLED
AS = Accu-Set™ pressure regulator (1 1/2" and
2" models only)
R = Reclaimed water indentification handle
DC = DC latching solenoid |
|